Operation Manual / 4 Product description / A100-M axial
5 Operation and service / 5.4 Stopping the engine
© Copyright 2019 ABB. All rights reserved. HZTL4033_DE Revision C February 2019
Expected replacement intervals [h]
Component GAS / MDO HFO
Gas inlet casing 50000 … 100000 25000 … 50000
Gas outlet casing 50000 … 100000 35000 … 100000
Nozzle ring 35000 … 50000 25000 … 50000
Turbine diffuser / cover ring 35000 … 50000 25000 … 50000
Other casings 100000 100000
Turbine blades (due to wear) - - 12000
Table8: Expected replacement intervals
GAS = Gas
MDO = Marine Diesel Oil
HFO = Heavy Fuel Oil
Recommended replacement intervals [h]
Rotor components See rating plate data
Bearings See rating plate data
Table9: Recommended replacement intervals
The specified values are guideline values and not guaranteed values, see Influencing para-
meters.
5.4 Stopping the engine
CAUTION
Stopping the engine
In the turbocharger, the heat from the lubricating oil that continues to circu-
late must be dissipated.
u Let the engine continue to run at idling speed for 10 minutes before stop-
ping it.
u Post-lubrication can also be used instead of engine idling (see Pre-lubric-
ation and post-lubrication 18).
Page 32 / 108