1.2
Cabling
Unit
1
Dismounting:
Reference
is
made
to
fold
out
no.
3
in
the
spare
parts
section.
L
2.
3.
4.
Dismount
the
covers
on
gear
boxes
2
and
3.
Unscrew
screws
<1:3/54>
for
the
cover
on
the
intermediate
plate
<2:1/2>,
and
loosen
the
covers
on
the
lower
arm
cabling.
Disconnect
cable
contact
X4
from
axis
1.
Disconnect
contacts
X6
-
X8
from
gear
box
3.
5a.
When
removing
av
refitting
the
measurement
board,
it
is
of
vital
importance
that
the
standards
regarding
ESD
protection
is
followed.
5b.
Remove
the
measurement
board
and
its
bracket.
Disconnect
X15.
5c.
Disconnect
contacts
X5/X13,
X14,
X28
and
X50
and
shieldings
from
gear
box
2.
6.
Disconnect
groundings
at
axes
2
and
3.
7.
Mount
lifting
tools,
lift
and
turn
the
robot
according
to
chapter
1,
Exchange
motor.
8.
Dismount
the
cover
<1:1/30>
from
the
base
<1>,
and
contacts
RX1,
RX2
and
X3.
9.
Disconnect
grounding
and
shielding
connections
for
cabling
unit
1.
10.
Cut
the
cable
ties.
11.
Unfasten
the
screws
holding
attachment
plate
for
cabling
unit
1.
12.
Pull
out
the
unit
downwards
and
feed
the
cabling
through
the
cabling
channel
in
the
intermediate
plate
at
the
same
time.
Mounting:
Reference
is
made
to
fold
out
no.
3
in
the
spare
parts
section.
13.
Insert
the
cabling
through
the
base
plate’s
center
hole.
N.B.
It
is
important
to
gather
the
cables
in
correct
order
when
they
are
inserted
through
the
cable
channels
to
avoid
unintentional
wear
to
the
cables.
Also,
axis
1
shall
be
in
calibration
position
0.
14.
Fit
the
rotator
and
fasten
it
from
the
under
side
with
the
screws.
15.
Fasten
the
cabling
unit
to
the
base
from
the
under
side.
16.
Refit
X15
and
the
bracket
and
fasten
the
ribbon
cable
shield
connection.
Connect
X5/X13,
X14,
X28
and
X50.
Refit
the
measurement
board.
17.
Connect
contact
X4.
18.
Connect
the
cable
contacts
for
signal
and
power
cabling,
X3,
X6-X7,
X8,
X12-X15,
RX1,
RX2
and
grounding
and
shielding
connectors
on
gear
boxes
1,
2
and
3.
Mechanical
repair
IRB
2000