Access to the monitoring data of UMC100.3 acc. to the UMC100.3 manual section
A1 parameters and data structures on a Fieldbus
Register Bit 7
Bit 15
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit1 Bit 0
Bit 8

Summary
Warning
Summary

Local Control Reverse
Lockout


warning


 Run
Reverse /
Closing
      Run


Access to the command data of UMC100.3 acc. to the UMC100.3 manual section
A1 parameters and data structures on a Fieldbus
Register Bit 7
Bit 15
Bit 23
Bit 31
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit1 Bit 0
Bit 8
Bit 16
Bit 24

 Auto Mode Prepare
Emergency
Start
Run


 Run
Reverse /
Closing
   

Run













Word oriented access to diagnosis data of UMC100.3 acc. to the UMC100.3 manual section
A1 Parameters and Data Structures on a Fieldbus
Register Bit 7
Bit 15
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit1 Bit 0
Bit 8

Checkback
missing
PTC wiring
failure
PTC hot 
thermal
model
Locked rotor
during

(stall)
Phase
imbalance
Phase
loss
Thermal
overload trip
Actuator
problem
UMC

Earth fault

Earth fault
trip (internal

triggered)
I
above high
current
warning
threshold
I
above high
current trip
threshold
I
below low
current
warning
threshold
I
below low
current trip
threshold

Trip/Warning
from

function
block

Trip/Warning
from

function

Trip/Warning
from

function

Trip/Warning
from

function

Trip/Warning
from

function

HW fault on

Custom
application
error

missing
Trip triggered
from
Multifunction

Trip triggered
from
Multifunction

Trip triggered
from
Multifunction

Trip / Warning

function


THD Warning 
spec

power
Underload
power
Cooling Time
Running
Just one start
left
Num Starts



diagnosis is
available.
Parameter
out of range

The function of some bits can differ in case the control functions Actuator 1...4, Overload Relay or Transparent are configured.Please refer to the UMC100.3 manual in this case.
14 UNIVERSAL MOTOR CONTROLLER UMC100.3 | MRP31.0 MODBUS TCP COMMUNICATION MODULE MANUAL