EasyManua.ls Logo

ABB REC650 - Page 10

ABB REC650
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preparing the IED to verify settings..................................................31
Activating test mode.........................................................................33
Preparing the connection to the test equipment...............................33
Connecting test equipment to the IED..............................................34
Releasing the function to be tested..................................................35
Verifying analog primary and secondary measurement...................35
Testing protection functionality.........................................................37
Section 6 Testing functionality........................................................39
Testing disturbance report................................................................39
Introduction..................................................................................39
Disturbance report settings..........................................................39
Identifying the function to test in the technical reference
manual .............................................................................................39
Testing current protection functions.................................................40
Instantaneous phase overcurrent protection PHPIOC ...............40
Measuring the operate limit of set values...............................40
Completing the test................................................................40
Four step phase overcurrent protection OC4PTOC....................40
Verifying the settings..............................................................41
Completing the test................................................................42
Instantaneous residual overcurrent protection EFPIOC .............42
Measuring the operate limit of set values...............................42
Completing the test................................................................43
Four step residual overcurrent protection EF4PTOC .................43
Four step directional residual overcurrent protection ............43
Four step non-directional residual overcurrent
protection................................................................................44
Completing the test................................................................44
Sensitive directional residual overcurrent and power
protection SDEPSDE ..................................................................44
Measuring the operate and time limit for set values...............44
Completing the test................................................................49
Thermal overload protection, one time constant LPTTR ............49
Completing the test................................................................49
Breaker failure protection CCRBRF............................................49
Checking the phase current operate value,
IP>
.....................50
Checking the residual (earth fault) current operate value
IN>
set below
IP>
...................................................................50
Checking the re-trip and back-up times..................................50
Verifying the re-trip mode.......................................................51
Verifying the back-up trip mode..............................................51
Verifying the case
RetripMode
=
Contact
...............................53
Verifying the function mode
Current&Contact
........................53
Table of contents
2
Commissioning Manual

Table of Contents

Other manuals for ABB REC650