Function IEC 61850 ANSI D F L N P
"Current transformer
supervision for
highimpedance
protection
scheme for phase B" HZCCBSPVC MCS

"Current transformer
supervision for
highimpedance
protection
scheme for phase C" HZCCCSPVC MCS

Fuse failure supervision SEQSPVC 



Runtime counter for
machines and devices MDSOPT OPTM





Measurement
Load profile record LDPRLRC LOADPROF
Three-phase current
measurement CMMXU IA, IB, IC
Sequence current
measurement CSMSQI 
Residual current
measurement RESCMMXU 
Three-phase voltage
measurement VMMXU VA, VB, VC


Residual voltage
measurement RESVMMXU 
Sequence voltage
measurement VSMSQI 
Single-phase power and
energy measurement SPEMMXU SP, SE
Three-phase power and
energy measurement PEMMXU P, E
     
Frequency measurement FMMXU f

sampled value sending
 SMVSENDER SMVSENDER    

sampled value receiving

 SMVRCV SMVRECEIVER    
Other
"Minimum pulse timer
  






pcs, second resolution)  






pcs, minute resolution)  





  





  





  





  SR





  MV







pcs)"  SPC





"Analog value scaling
  





"Integer value move
  






counters UDFCNT CTR





Table 2. Supported functions, continued
12 REF615 ANSI 5.0 FP1 FEEDER PROTECTION AND CONTROL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB REF615 ANSI 5.0 FP1 and is the answer not in the manual?

ABB REF615 ANSI 5.0 FP1 Specifications

General IconGeneral
Rated Frequency50/60 Hz
Binary OutputsUp to 8
Device TypeFeeder Protection Relay
Version5.0 FP1
Protection FunctionsOvercurrent, Earth Fault, Thermal overload, Under/Overvoltage, Under/Overfrequency
Communication ProtocolsIEC 61850, Modbus, DNP3
Auxiliary Supply Voltage110-250 V DC/AC
MountingFlush mounting
Operating Temperature Range-40 °C to +70 °C
Dimensions177 x 177 x 150 mm (H x W x D)
HousingPlastic
StandardIEC 60255
Input Voltage110-240 V AC/DC
EnclosureIP54