78 REF615 ANSI 5.0 FP1 FEEDER PROTECTION AND CONTROL
Table 119. Functions included in the relay (continued)
Function IEC 61850 ANSI
Interconnection functions
Directional reactive power undervoltage
protection  
Low-voltage ride-through protection
 
 
 
Voltage vector shift protection
 
Power quality
Current total demand distortion
 
Voltage total harmonic distortion
 
Voltage variation
 
Voltage unbalance
 
Control
Circuit-breaker control
 
Disconnector control
 
 
Earthing switch control
 
Disconnector position indication
 
 
 
Earthing switch indication
 
 
Autoreclosing
 
Synchronism and energizing check
 
Condition monitoring and supervision
Circuit-breaker condition monitoring
 
Trip circuit supervision
 
 
Current circuit supervision
 
Current transformer supervision for high-impedance protection scheme for
phase A  
Current transformer supervision for high-impedance protection scheme for
phase B  
Current transformer supervision for high-impedance protection scheme for
phase C  
Fuse failure supervision
 
Runtime counter for machines and devices
 
Measurement
Disturbance recorder
 
Load profile record
 
Fault record
 
Three-phase current measurement
 
Sequence current measurement
 
Residual current measurement
 
 
Three-phase voltage measurement
 
 
Residual voltage measurement
 
Sequence voltage measurement
 
Three-phase power and energy measurement
 

 
Frequency measurement
 

SMVSENDER SMVSENDER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB REF615 ANSI 5.0 FP1 and is the answer not in the manual?

ABB REF615 ANSI 5.0 FP1 Specifications

General IconGeneral
Rated Frequency50/60 Hz
Binary OutputsUp to 8
Device TypeFeeder Protection Relay
Version5.0 FP1
Protection FunctionsOvercurrent, Earth Fault, Thermal overload, Under/Overvoltage, Under/Overfrequency
Communication ProtocolsIEC 61850, Modbus, DNP3
Auxiliary Supply Voltage110-250 V DC/AC
MountingFlush mounting
Operating Temperature Range-40 °C to +70 °C
Dimensions177 x 177 x 150 mm (H x W x D)
HousingPlastic
StandardIEC 60255
Input Voltage110-240 V AC/DC
EnclosureIP54