I/O Modules Section 2 Product Description
50 3BSE015969-600 A
AI880/
AI880A
(2)
High Integrity Analog Input 1*8 channels. 0...20 mA,
4...20 mA
For single and redundant applications.
AI880A has support for HART pass-through
communication.
Complies with the NAMUR recommendation NE43.
AI890 Analog Input 1*8 channels. 0…20 mA, 4...20 mA,
12 bit, 0.1% I.S. interface.
Rated insulation voltage 50 V
AI893 Analog Input 1*8 channels for 2- or 3-wire RTD and
Thermocouple
RTD: Pt..., Ni..., Cu... and linear
TC: B, C, D, E, J, K, L, N, R, S, T, U and linear
15 bit + sign, I.S. interface
Rated insulation voltage 50 V.
AI895 Analog Input 1*8 channels. 4...20 mA,
12 bit, 0.1% I.S. and HART interface.
Rated insulation voltage 50 V.
AO801 L Analog Output 1*8 channels, 0…20 mA,
4...20 mA, 12 bit, 0.1%.
RL maximum 850 Ohms.
Rated insulation voltage 50 V.
AO810/
AO810V2
Analog Output 1*8 channels, 0…20 mA,
4...20 mA, 14 bit, 0.1%.
RL maximum 500/850 Ohms.
Rated insulation voltage 50 V.
AO815 Analog Output 1*8 channels, 4...20 mA, 14 bit, 0.1%.
RL maximum 750 Ohms.
Rated insulation voltage 50 V.
Table 7. S800 Analog Modules (Continued)
Module
Type
Type
(1)
Description

Table of Contents