EasyManua.ls Logo

ABB ScreenMaster RVG200 - Health and Safety Information; Safety Precautions, Hazards, and Standards

ABB ScreenMaster RVG200
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SCREENMASTER RVG200 / PAPERLESS RECORDER | CI/RVG200/001-EN REV. A
7
Analog input / relay / hybrid connections
IMPORTANT (NOTE)
Tighten terminal screws to a torque of 0.1 Nm (0.9 lbf.in).
Analog inputs:
3-Lead RTD: 3-leads must have equal resistance, not exceeding 20 W each
for mA input types, to ensure loop continuity when the recorder is switched off, fit a suitably-rated diode
(for example, type 1N4148 or equivalent)
3
11
10
9
8
7
6
5
4
1
2
18
17
16
15
14
13
12
3
11
10
9
8
7
6
5
4
1
2
18
17
16
15
14
13
12
3
11
10
9
8
7
6
5
4
1
2
13
12
L
N
+
Tx +
Tx
Tx / Rx
+
3
11
10
9
8
7
6
5
4
1
2
18
17
16
15
14
13
12
+
*
Tx / Rx
1
2
3
4
5
6
1+
2+
3+
4+
5+
Cold junction
*Each thermocouple input must have either a cold junction assembly (part number CM30/0052) or shorting link (part number
RVG200/0118) fitted. Each analog input card with a thermocouple input must have a minimum of 1 cold junction assembly fitted.
Inputs 1 to 6
RTD
R
THC
Volt-free
digital input
mV, V, ma,
digital input (V)
A, B, C, D
Analog Input
A, B, C, D
Relay
C, D
Hybrid
E
Power supply
RJ45
USB
100 to
240 V AC
24 V
DC
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
N/C
N/O
C
N/C
N/O
C
N/C
N/O
C
N/C
N/O
C
N/C
N/O
C
N/C
N/O
C
Analog or digital outputs
Tx PSU
Digital inputs
Common
Communications
common
Figure 5 Analog input / relay / hybrid connections
Connecting a 2-lead temperature transmitter
Figure 6
1
++
+
+
+
_
_
_
_
2
3
1
2
3
4
1
2
3
4
24 V DC
Current limited
to 22.8 mA
maximum
2-wire
transmitter
A, B, C, D
Analog input
Input 1
2-wire
transmitter
Analog
input
Input 1
Hybrid
Analog or digital output 1
Tx PSU 1
Analog or digital output 2
Tx PSU 2
Using an internal Tx power supply or hybrid board
Using an external 24 V power supply
* In the powered-down condition the current input is open circuit. In order to maintain a current loop when the
recorder is powered down, fit a zener diode (BZX79 – B/C2V4) to the input as shown.
Connecting a 2-wire temperature transmitter