Operation Manual / TPL73-B.. - 85-B11/ -B12
9 Shut-down at short notice / 9.5 Fit cover plate
© Copyright 2018 . All rights reserved. HZTL2480_EN Revision D July 2018
Further measures and information for operation with a
turbocharger with cover plate in 2-stroke engines
2-stroke engine with one turbocharger:
No further measures are necessary. The engine can be operated with the
auxiliary blower according to the manufacturer's instructions.
2-stroke engine with several turbochargers:
u Block air line on engine side as undamaged turbochargers develop a
receiver pressure.
u Significantly raise operating limit of engine by blocking the gas inlet
additionally as exhaust gas is then used to drive undamaged tur-
bocharger.
CAUTION
Attention must be paid to the speed of the undamaged turbochargers
in all cases. The speed limit n
Bmax
according to the turbocharger rating
plate must not be exceeded.
NOTICE
Basically, the engine can be operated according to the engine manufac-
turer's instructions.
Page 141 / 151

Table of Contents