EasyManua.ls Logo

ABB TPL76-C - Page 55

ABB TPL76-C
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / TPL76-C
5 Maintenance / 5.3 Cleaning the compressor during operation
© Copyright 2020 . All rights reserved. HZTL2485_EN Rev.G March 2020
5.3.2 Wet cleaning using external water-pressure vessel
(XC3)
Operating state prerequisites for compressor cleaning with XC3
To be able to carry out a satisfactory cleaning process which has been
tested and is recommended by ABB Turbocharging, the following pre-
requisites must be fulfilled:
u Engine load 50 – 85%
u Start cleaning cycle according to following description Wet cleaning
operation with XC3.
Operating procedure for compressor wet cleaning with XC3
Operating the water pres-
sure vessel
u The operating state prerequisites for compressor cleaning with XC3
must be fulfilled.
u Remove sealing plug (X).
u Fill vessel with required volume of clean water (see table Cleaning
parameters).
u Screw in sealing plug (X).
u Push the valve activator (Y) against the spring and hold it for 10...15
seconds until the entire volume of water has been injected.
Page 53 / 133