Operation Manual / TPS44-F.. - TPS61-F..
St
art-up
3
Oil supply
3.1
Page 37
April 2015 HZTL2412_EN Revision E
Oil pressure
The oil pressure in front of the turbocharger must be maintained precisely
to ensure trouble-free operation.
Status for operation
Oil pressure in front of
turbocharger
[bar]
Normal operation
2.04.5
Engine start: cold oil, permissible for maximum 15
minutes
8.0
Engine idling
0.2
Pre- and post-lubrication (engine stopped) 1.0
CAUTION
Prelubrication
Serious machine or property damage might result if the turbocharger is
not supplied with oil when the engine is starting.
Activate prelubrication device before starting engine.