- 19 -
000469AG
UNO-2.0-TL-OUTD UNO-3.0-TL-OUTD
Communication
Remote Monitoring VSN300 Wi Logger Card (opt..), VSN700 Data Logger (opt.)
Wireless local monitoring VSN300 Wi Logger Card (opt.)
User Interface LCD Display with 16 characters x 2 lines
Wired local monitoring PVI-USB-RS232_485 (opt.)
Available ports RS485, Remote ON/OFF, Alarm Relay
Expansion slot 1
Environmental
Ambient temperature
-25...+ 60 °C/-13...140 °F
with derating above 45°C / 113°F
Relative Humidity 0...100% w/o condensation
Typical noise emission pressure 50 dB(A) @ 1 m
Maximum operating altitude without derating 2000 m / 6560 ft
Environmental pollution degree
classication for external environments
3
Environmental category Outdoor
Physical
Environmental Protection Rating IP 65
Cooling System Natural
Dimensions (H x W x D) 553mm x 418mm x 175mm / 21.8” x 16.5” x 6.9”
Weight 12 kg / 26.5 lb
Assembly System Wall bracket
Overvoltage rating as per IEC 62109-1 II (DC input) III (AC output)
Safety
Safety class I
Insulation Level Without transformer (TL)
CE Marking (50 Hz Only)
Safety and EMC Standards
IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3,
EN 61000-3-2, EN 61000-3-3
Other features
Function for managing loads GoGo Relay
1. The output voltage range may vary according to the grid standard of the country of installation
2. The output frequency range may vary according to the grid standard of the country of installation
3. In the event of a fault, limited by the external protection envisaged on the AC circuit
4. Please refer to the document “String inverters – Product manual appendix” available at www.abb.com/solarinverters for informa-
tion on the quick-t connector brand and model used in the inverter
.
Note. Features not specically mentioned in this data sheet are not included in the product