- 48 -
000478AG
5 - Installation
During installation do not place the
inverter with the front cover
05
fa-
cing the ground.
Position the bracket
01
so that it is
perfectly level on the wall and use it
as a boring template.
• Make the 2 holes necessary using a
drill with a 10 mm. diameter bit. The
depth of the holes must be approxim-
ately 70 mm.
Secure the bracket to the wall with
the two 10 mm wall plugs supplied.
Attach the inverter by inserting the
two tabs on the bracket
01
into the 2
slots on the inverter (gures A1 and
A2).
Secure the inverter to the bracket by
screwing the lock screws
02
on both
sides of the inverter (gure A3).
The main connections of the inverter
are carried out externally without the
need to remove the front cover. If ne-
cessary, unscrew the 8 screws and
open the front cover
05
.
Do not open the inverter
in the case of rain, snow
or a high level of humidity
(>95%)
Once the connections have been
made inside the inverter, close the
cover by tightening the 8 screws on
the front, respecting the sequence
and tightening torque (see specic
paragraph on "Closing the front
cover").