- 76 -
000513AG
7 - Operation
Firmware update
The rmware can be easily updated by means of a microSD Card (4GB
maximum capacity).
The latest rmware version is available from the download area of the
website www.abb.com/solarinverters or from https://registration.
abbsolarinverters.com
Perform the update during good irradiation conditions (avoid the dawn and dusk hours)
• Format the microSD card using a "FAT32" File System
Save the (.tib) update le on the microSD Card. The le must not be
compressed and/or nested inside folders
• Switch the inverter off by physically disconnecting the AC and DC side,
as well as any voltages connected to the multi-function relay, then open
the inverter front cover.
• Insert the microSD Card in the dedicated memory card slot
12
• Carry out the procedure for the commissioning of the inverter
The inverter shows the “Update Available” message on the display.
- Press ENTER
- Select “>>START UPDATE” using the UP and DOWN keys
- press ENTER to conrm the start of the rmware update process
Once the rmware update has been launched, no operations need to be carried out on the
inverter as the 5 processes of the update will complete automatically.
At the end, the message “Update COMPLETED” will appear on the
display and by pressing any key, the result of the updates of the devices
inside the inverter will be shown
Supervisor OK
G.Settings OK
Language OK
DC/AC OK
Safety OK
The inverter rmware can be updated also by using the accessory boards. For further inform-
ation, refer to the website or contact ABB.