Configurable Relay connection (ALARM / LOAD MANAGER)
The UNO-DM-COM KIT board is equipped with a relay with congurable
activation that allows connection of external devices which for example,
signal malfunctions to manage loads with a specic congurable power
input threshold, according to the mode selected in the specic section of
internal webserver (see the specic chapter). The connection must be
made to the specic ALARM terminal block
24
.
K1
J2
J3
1
J4
MP1
-T/R
RTN
RTN
RS485REM
+T/R
+R
120
TERM.
ON
OFF
DRM0
N.C.
N.O.
ALARM
C
UNO-DM-COM KIT
04
The congurable relay can be used with normally open contact (being
connected between the NO terminal and the common contact C) and
with normally closed contact (being connected between the NC terminal
and the common contact C).
Different types of devices (light, sound, etc.) can be connected to the
relay, provided they comply with the following requirements:
Relay Rating:
Maximum Voltage: 230 Vac
Maximum Current: 1 A
The cable specications are described in the following table:
AWG Operating voltage Operating temperature
22 - 24 ≥300 V -20...+60 °C
This contact can be used in different operating congurations that can be
selected by accessing the specic section of internal webserver (refer to
the specic chapter).