2000 advanced/2000 10 Troubleshooting
does not function
• Power supply interrupted
• Check the electric system and repair
if necessary
• Motor/coolant pump defective
• Replace the motor/coolant pump
• Contact the service department
• Replace the fuse (basic)
• Press to reset the fuse
6.3 Before Initial S
tartup and
Commissioning on Page EN-13
or non-existent
• No coolant in the coolant tank
• Blockage or foreign object in the coolant
circulation loop
• Check coolant hoses and connections
• Rinse coolant circulation loop
• Coolant pump fuse defective
6.3 Before Initial S
tartup and
Commissioning on Page EN-13
• Replace the defective component
• Check the coolant circulation loop
connections
• Coolant circulation loop interrupted
• Check coolant hoses for damage
• Air in the coolant circulation loop
• Venting
6.3.1 Venting on Page EN-14
• Due to long-term idling, maintenance or other
reasons, the circulation loop has been emptied
• 10.1 Forced venting of the
circulation loop
low
• Replace the defective component
• Contact the service department
• Replace the defective component
• Cooling unit with too low cooling capacity
connected
• Contact the service department
• Blow dry compressed air through the
cooling unit
• Use a cooling unit with a higher
cooling capacity
• Replace the defective component
• Check hose guides, correct if
necessary
• Coolant temperature too high
• Replace the defective component
• Contact the service department
• Check whether the fan is functioning
correctly
Table 8 Troubleshooting
EN - 18