41
LED presets
Only green LEDs
Only blue LEDs
Both LEDs
6. ERROR MESSAGES
Sequence F8
The Wallbox has detected a short circuit between the Pilot Contact CP
and the Protective Earth conductor PE
1 The Wallbox automatically reini-
tiates the charging procedure
every 60 seconds
2 If the error continues to occur,
take the Wallbox out of opera-
tion permanently.
Shutdown: p. 54
Contact your specialist electrical
contractor to check the charging
cable and the Wallbox for cor-
rect functioning
3 If no fault could be detected with
the charging cable, check the
vehicle. Contact a qualified spe-
cialist repairer for this purpose
The green LED flashes twice
The blue LED is continuously Off
200ms 200ms 200ms 200ms200ms200ms200ms200ms200ms200ms