27
PROGRAMMING
DISPLAY BRIGHTNESS
To adjust the brightness of the display, set the controller to OFF Mode, then press the up or down
button to increase or decrease the brightness level. Four brightness settings are available.
FAHRENHEIT OR CELSIUS
To change to displayed units between Fahrenheit and Celsius, set the controller to OFF Mode, then
hold the up button for Fahrenheit (°F) or hold the down button for Celsius (°C).
ECO-MODE
The controller can be put into ECO display in which the screen will be turned off but all programs,
settings, and alarms will be running in the background. This can be done by pressing the LEAF
button. You may also do this while the controller is locked. To exit ECO display, simply press any
buttons.
TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, press the MODE and UP button
simultaneously. This can be done while the controller is any mode or setting. The calibration cycle
ranges from -8°F to 8°F (or -4°C to 4°C) and will be applied to the probe sensor’s measurements.
HUMIDITY CALIBRATION
To adjust the humidity that the probe sensor is measuring, press the MODE and DOWN button
simultaneously. This can be done while the controller is any mode or setting. The calibration cycle
ranges from -8% to 8% and will be applied to the probe sensor’s measurements.
CONTROLLER LOCK
To lock the controller to prevent settings to be changed accidentally, hold the LEAF button for two
or more seconds. While the display is locked, you will not be able to switch modes or changes any
settings. You will only be able to put the controller in ECO display by pressing the LEAF button.
Holding the LEAF button for two or more seconds will unlock the controller.