EasyManuals Logo

AC Tech Lenze SV01B User Manual

AC Tech Lenze SV01B
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
ENGLISH
ESV…N01S…
ESV…N01S… ESV…N01S…
ESV…N02Y…
(2/PE AC)
ESV…N02Y…
(
1/N/PE AC)
ESV…N02S…
(2/PE AC)
ESV…N02S…
(
1/N/PE AC)
9
Installation
3.2 Electrical installation
3.2.1 Power Connections
DANGER!
Hazard of electrical shock! Circuit potentials are up to 600 VAC above earth ground.
Capacitors retain charge after power is removed. Disconnect power and wait at least
three minutes before servicing the drive.
STOP!
Verify mains voltage before connecting to drive.
Do not connect mains power to the output terminals (U,V,W)! Severe damage to the
drive will result.
Do not cycle mains power more than once every two minutes. Damage to the drive
will result.
3.2.1.1 Mains connection to 120VAC Single-Phase Supply
PE L1 L2 N
PE L1 N
3.2.1.2 Mains connection to 240VAC Single-Phase Supply
PE L1 L2 N
PE L1 L2
PE L1 L2 N
PE L1 N
PE L1 L2 L3
PE L1 L2
PE L1 L2 L3
PE L1 N
PE L1 L2
PE L1 L2
PE L1 L2
PE L1 N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AC Tech Lenze SV01B and is the answer not in the manual?

AC Tech Lenze SV01B Specifications

General IconGeneral
BrandAC Tech
ModelLenze SV01B
CategoryInverter
LanguageEnglish