7. Tare and Remove Tare
a) Tare: When Tare status LED is off and the weight is 0 and stable, press→T← to acquire
tare and switch to net mode, the tare status LED is turned on.
b) Remove tare: When Tare status LED is on, press→T← will switch to gross mode and
removed tare. The tare status LED is off.
8. Battery Capacity
When after turn on indicator, displaybt 85is battery capacity.
9. Low Battery Warning
When the battery is capacity less than 10% of full charge, display will flash. When the battery has
no power, the indictor display bAtt turn off immediately.
10. LED Error Code
Display OUEr, weight > FS + 9d, display –OUEr , weight < -2% FS, Display Error,
calibration error.