19
For Redundant Power Supply
Item Description
Model
DPS-500WB A+RPS-450-1 E
Type
400W
Dimensions
Height
Depth
Width
40.0 mm (1.57 in.)
316.9 mm (12.47 in.)
96.8 mm (3.81 in.)
Weight (approximate) 2.13kg (4.7 lb)
Input requirements
Rated input voltage
Normal line voltage
100–127 VAC/ 6.5A , 200–240 VAC/ 3.0A
115 VAC, 230 VAC
Line frequency
47–63 Hz
Rated input current Load 6.5A at 100–127 VAC, 3.0A at 200-240 VAC
Inrush current
No damage
Power supply output power
Rated steady state power
Maximum peak power
360W at 100-127VAC, 400W at 200 – 240VAC
360W at 100-127VAC, 400W at 200 – 240VAC
Operating conditions
Temperature
Humidity (non-condensing)
5–45  °C (41–113°F)
5-85% at +45C