- 37 -
5.1.3 ADC calibration (Auto color balance adjustment)
~~Analog only, it is not required for DVI-D input source
1. Setup input timing ICL-605( 1280x1024@75Hz ), pattern 42(5-Mosaic pattern with white
color block) with Analog signals from Chroma video pattern generator. (it depends on Scaler
IC supplier’s recommendation)
2. Enter factory mode (press “e-Key” & “Power” buttons at the same time to turn on monitor).
3. Move cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4. Close OSD menu then press “Auto” button for auto color adjustment. (This procedure will
get optimal gain/offset(clamp) values)
5. Checking if the picture is ok, or reject this monitor and check its circuit board or wire/cable
connection.
5.1.4 Color temperature adjustment
1. Setup input timing to any preset modes, pattern 41(full white color pattern) with Analog
signals from Chroma video pattern generator.
2. Enter factory mode (press “Empowering” & “Power” buttons at the same time to turn on
monitor).
3. Move cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4. Make sure ADC calibration (auto color balance adjustment) had already been done.
5. Measure color temperature by Minolta CA-110 (or equivalent equipment).
6. Adjust the color temperature ~~ Two methods can be used to adjust RED, GREEN, BLUE
value of each color temperature, C1/Cool, C2/ Warm & C3/ User to meet following spec
requirement, the 1
st
method is by using external PC and IIC alignment protocol to do
automatic adjustment, and the 2
nd
method is by manually and must be in factory mode.
X+- 0.283+(-) 0.03
Y+- 0.297+(-) 0.03
Color temperature
(C0/cool on OSD)
Luminance > 180 cd/m²
X+- 0.313+(-) 0.03
Y+- 0.329+(-) 0.03
Color temperature
(C2/Warm on OSD)
Luminance > 220 cd/m²
X+- 0.313+(-) 0.03
Y+- 0.329+(-) 0.03
Color temperature
(C3/User on OSD)
Luminance > 220 cd/m²
7. Move cursor into “Burn-in Mode” tag and select “No” to disable burn-in mode.
8. Turns off the monitor power.