4
1.2 General Requirements:
1.2.1 Test Condition:
All tests shall be performed under the following conditions, unless otherwise specified.
Warm up time > 30 min.
AC supply voltage 230V± 5%, 50± 3 Hz
Ambient temperature
20C 5C
Humidity
65%20%
Display mode
1440x900,60Hz,PixelClock106.5MHZ,allwhite
e-color mode Set to “User” mode
Contrast control Set to The value under user mode, which allows that the
brightest two of 32 linear distributed gray-scales (0 700mv)
can be distinguished.
Color temperature 6500°K
Brightness control The value under user mode
Analog Input signal 700 mVss
Picture position and size Factory preset value,
Viewing angle 90 ° H and V
Viewing distance 40 cm for LCD performance, 20 cm for LCD failures
Ambient illumination Dark room (< 1 cd/m