Condential
4-3
X1161/X1261
Order Symptom Pattern Criteria
1 Bright pixel ( dots)
Black pattern
( IRE=O)
A+B=0
2 Dark pixel(dots) White pattern A+B=4
3 Unstable pixel (dots) White & Black pattern A+B=0
4 Adjacent dark pixel (dots) White pattern A+B=0
5 Bright blemish (Dirty) Gray 10 pattern
A+B=4
(diameter <1/2 inch)
6 Dark blemish (Dirty) Blue 60 pattern
A+B=4
(diameter <1/2 inch)
7 Bright dot on frame Black pattern 1
4-5 Test Inspection Procedure
Update
Change parts
Main
Board
Firmware
Color
Wheel
Lamp
Module
Engine
Module
EDID
Lamp
Driver
Version Update v v v
Color Wheel Index v v
PC Calibration v v
Video Calibration v v
G Sensor Calibration v v
Reset Lamp Hour v
OSD Reset v v
EDID v
Re-write Lamp
Hour Usage
v
Reset Default
Language
v v v v
Rod adjustment v
Waveform Download v
Note: - If Color appears abnormal after changing Main Board Module, please do Color Wheel index
adjustment.
- After changing parts, check the information above table.