1.2 General Requirements:
1.2.1 Test Condition:
Normal test condition is that brightness level set at Max. and contrast level set default. Test pattern is full
white pattern. The warm up time is more than 30 minutes. Ambient light should be less than 1 Lux.
1.2.2 Test Equipment:
The reference signal source is a calibrated Chroma 2326 or Quantum 801GD video generator. The use of
compatible generators during qualification and production is acceptable. Luminance meter is Minolta CA210,
TOPCON BM7 or compatible equipment.