21
7-2. Functions
a) Antenna Impedance Matching Process: plate-load True Resistance Indicator (TRI) aided.
b) T/R System: QSK operation with built-in, vacuum RF antenna relay (special quiet installation).
c) Protections:
- Cover interlock for operators safety;
- Inrush power-on current control;
- High voltage, control grid, screen grid, and plate currents;
- Exhaust air temperature;
- T/R sequencing;
- Antenna relay contacts, including RF power induced in antenna from another nearby transmitter;
- Antenna matching quality;
- Reflected power;
- RF arcs, including in antenna system;
- Overdrive.
d) Signatures of the amplifier internal status are stored in a nonvolatile memory for the seven most
recent auto protection trips.
e) Dot matrix backlighted alphanumeric LCD with bargraph for forward peak power and text messages
to the operator.
f) Measurement and constantly monitoring of 12 most important parameters of the amplifier via LCD.
g) Menu-selectable LCD Backlight and Contrast.
h) Tube: a single 4CX800A (GU74B) high-performance ceramic-metal tetrode of Svetlana with plate
dissipation of 800W, grid driven, forced air-cooling.
7-3. Storage and Shipment
C A U T I O N
Should you need to transport the amplifier, use the original packing as described
below.
First, switch off the amplifier. Pull the mains plug out of the outlet. Disconnect all cables from the rear
panel of the amplifier (remove the ground connection the last). Finally, pack the amplifier in its original
carton.
a) Storage environments: the amplifier can be kept packed in dry and ventilated unheated premises
without chemically active substances (acids, alkalis etc.) in the following climatic environment:

Other manuals for Acom ACOM1000