25
Plug in two HV Fast-on connectors to the HV Rectier board
C A U T I O N
Insert the two rubber grommets (readily threaded on each transformer HV
lead) in the intended chassis-wall slots in order to protect both HV leads from
sharp metal edges. Make sure the grommets t the slots fully and properly.
Thread the 8 primary leads of the HV-transformer (labeled with numbers 1 - 8) through the
opening in the sub chassis carrying the Mains PCB.