ERROR REPORTS
Feature T700 A130
Safety edge activated (footrest down/under plate) E1
Check for obstructions or footrest wire connections.
Safety edge activated (footrest up) E2
Check for obstructions or footrest wire connections.
Safety edge activated (cover down) E4
Check for obstructions or wire connections.
Safety edge activated (cover up) E5
Check for obstructions or wire connections.
Seat not in place (swivelled) E6
Place the seat back in the travelling position.
Check switch positioning or wire connection.
Battery low, upward movement inhibited E7
Drive the lift down the rail to the closest charge point and leave to recharge.
E7 will clear automatically once the lift has reached a safe battery charge to drive.
Aux switch operated while seat is not swivelled
(powered swivel units only)
E8
The additional seat swivel switch circuit has opened, when the lift was in the travel
position. Check the operation of the additional switch. The circuit should remain
close during travel .
Key switch o E9
Check the key is in and turned to on position.
FAULT CODES
24
FATAL ERRORS
Feature T700 A130
Relay fault F1
Remove power supply and Isolate batteries from the PCB to reset the controller.
If persistent, replace PCB. Tapping the relay could temporally clear the fault.
Brake fault F2
Check battery voltage and brake connections.
Motor over current fault F3
The current demanded by the motor has exceeded the threshold set.
Check the rail for obstructions or debris