23
FAULT CODES
NORMAL OPERATION
Feature T700 A130
Lift ready to use (beeping as no charger present) A1
Lift moving up (arm) A2
Lift moving down (arm) A3
Lift moving up (remote) A4
Lift moving down (remote) A5
Lift waiting for auto hinge to operate A9
AT CHARGING POINTS
Feature T700 A130
Low battery voltage level- trickle charge active C1
Low battery voltage level - half charge active C2
Medium Battery voltage level - full charge active C3
Medium battery voltage level - half charge active C4
High battery voltage level - Sustained charge ac-
tive
C5
Battery full - No charge active C6
Power Supply voltage too low C7
Check charge point internal wiring and power supply.
Power Supply voltage too high C8
Check charge point internal wiring and power supply.
Battery fault C9
Check batteries connection and reset PCB. If persistent, replace the batteries.