Acorn Stairlifts User Manual
5
5
T700 - CONTROLLER INFORMATION
LOW BATTERY PROCEDURE F5 E7
In the event of the stairlift entering a low battery level
during travel, you will experience the following:
• The lift will stop and display F5 (battery flat) with an
audible warning, reverting to E7 after the arm
toggle or remote is activated.
• The stairlift will ONLY drive in the downwards
direction displaying E7, until the bottom parking
position is reached.
• The display code E7 will remain and will automatically
clear once the batteries have recharged to a safe level.
HIBERNATION MODE
The Stairlift will enter hibernation mode after 60 seconds,
if the unit is positioned away from a charge point or in the
event of a power cut. The display will turn o, which will
reduce energy consumption.
In hibernation mode, the Stairlift will beep twice every
approximately 40 seconds, only by pressing a directional
switch from the arm or remote control will return the lift
to normal operation.
REMOTE CONTROL OPERATION
The T700 operates using Infrared (IR). This is
selected using the “Setting Mode” menu.
• Infrared
This technology requires line of sight with the stairlift
to operate correctly. There are 4 operating
channels available.
Note: RF technology is available when experiencing IR interferences