Questions and Answers

  • A
    Alyssa SmithSep 2, 2025
    Why is the wireless controller display dim on my Acson Air Conditioner?
    • N
      Nicole WarrenSep 2, 2025
      If the wireless controller display for your Acson Air Conditioner is dim, the batteries may be discharged. Replace them with new ones. Also, ensure the batteries are correctly inserted and that the assembly is proper.
  • W
    William HartSep 2, 2025
    What to do if water is flowing out of my Acson A5MSY18BR?
    • S
      Sean HenrySep 3, 2025
      To address the issue of water flowing out from your Acson Air Conditioner, switch off the unit and contact your nearest dealer. This problem might be due to tilted installation.
  • M
    Michael WilsonSep 3, 2025
    How to remove bad odor from Acson Air Conditioner?
    • A
      Andrew WalkerSep 3, 2025
      To address a bad odor from the discharge air flow of your Acson Air Conditioner, contact your nearest dealer. The odor may be caused by cigarettes, smoke particles, perfume, or other substances that have adhered to the coil.
  • J
    Jenna CalderonSep 4, 2025
    What does Error Code UF mean on my Acson Air Conditioner?
    • J
      Jeffrey CruzSep 4, 2025
      If your Acson Air Conditioner is displaying Error Code UF, there is a communication error related to the piping and wiring between the indoor and outdoor units. Check the wiring and piping, refrigerant level, and refrigerant line for any blockages.
  • J
    Johnny WilsonSep 5, 2025
    What does Error Code A5 mean on my Acson A5MSY18BR Air Conditioner?
    • E
      Eric PearsonSep 5, 2025
      If your Acson Air Conditioner is displaying Error Code A5, it indicates an antifreeze issue. Check the air passage, intake air filter, dust accumulation on the indoor coil, wiring and piping, EXV, indoor coil sensor resistance value, refrigerant level, and room sensor resistance value.
  • W
    William HillSep 6, 2025
    What does Error Code E4 mean on my Acson A5MSY18BR?
    • A
      Amy ThomasSep 6, 2025
      If your Acson Air Conditioner is displaying Error Code E4, it indicates low pressure protection. Check the stop valve, low pressure sensor connection, low side pressure and voltage, outdoor coil sensor connection, sensor resistance value, and refrigerant level.
  • J
    Joseph LopezSep 6, 2025
    What does Error Code E5 mean on my Acson Air Conditioner?
    • T
      tdunnSep 7, 2025
      If your Acson Air Conditioner is displaying Error Code E5, it indicates a compressor motor lock or overload. Check the connection on the discharge pipe sensor, discharge pipe sensor resistance value, the EXV, and the refrigerant line for blockage or shortage.
  • C
    Christopher AndersonSep 7, 2025
    What does Error Code E9 mean on my Acson A5MSY18BR Air Conditioner?
    • J
      johnsonmaureenSep 7, 2025
      If your Acson Air Conditioner is displaying Error Code E9, it indicates an EXV error. Restart the system and check the EXV connection, EXV coil resistance and sensors resistance value.