Question and Answer IconNeed help?

Do you have a question about the ACT AC2300 and is the answer not in the manual?

ACT AC2300 Specifications

General IconGeneral
Capacity2300VA / 1380W
Output Power1380W
TopologyLine Interactive
Waveform TypeSimulated Sine Wave
Interface PortUSB
Form FactorTower
Input Frequency50/60Hz
Output Frequency50/60Hz
Battery Backup TimeVaries by load
Transfer Time4-6 ms
Device TypeLine Interactive UPS
Input Voltage220-240VAC
Output Voltage220-240VAC

Summary

1.0 Introduction

1.1 Functions and features

Details the product's capabilities and backup functions for data protection during power failures.

1.2 Packing contents

Lists the items included in the UPS package for user verification.

2.0 Remarks about Safety

3.0 Working Principle

3.1 In AC mode

Explains how the UPS filters AC power, charges the battery, and supplies the connected equipment.

3.2 AC Failure

Describes how the battery supplies power to the inverter during an AC power outage.

3.3 UPS outputs

Details the number and type of outputs for surge protection and battery backup on AC2300 and AC2305 models.

3.4 Battery and Charging

Covers the battery charging time and procedures for optimal battery health and longevity.

4.0 Main Features

4.1 Unattended Operation

Explains how the UPS automatically turns on/off and supplies power during AC failures and recovery.

4.2 Protection

Describes battery discharge protection and short-circuit protection mechanisms within the UPS.

4.3 Four Kinds of Alarm Function

Details the audible alarms for AC failure, low battery, overload, and fault conditions.

4.4 Lock Phase Function

Explains how the system synchronizes output waveform with AC voltage for reduced interference.

4.5 The Function of the Self-set Frequency

Describes the UPS's ability to automatically set its frequency to 50Hz or 60Hz based on AC input.

5.0 UPS Led

6.0 Installation and Operation

7.0 Maintenance

7.1 Preventative Maintenance

Outlines monthly checks to ensure the UPS is clean, ventilated, and properly connected for optimal performance.

7.2 Battery Maintenance

Provides steps for checking battery health by simulating AC failure and measuring discharge time.

7.3 Handling of abnormity

Offers troubleshooting steps for common UPS issues like power supply failure or non-response.

8.0 Frequently Asked Questions and other related information

9.0 Service and support

10.0 Warning and points of attention

11.0 Warranty conditions