3
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
UV Light in operation; do not operate unless the unit is completely and
correctly assembled; failure to follow warnings may result in
severe eye damage and electrical shock
To prevent damage to the unit, operating environment temperature must
never exceed 200
o
F (93
o
C)
To reduce the risk of electric shock, this equipment may have a grounding
type plug that has a third (grounding) pin; this plug will only fit into a
grounding type power outlet; if the plug does not fit into the outlet, contact
qualified personnel to install the proper outlet; DO NOT alter the plug in any
way
This unit is equipped with a universal ballast that operates at nominal
voltages between 120 and 240 VAC, 50/60 Hz
To Reduce the Risk of Electric Shock – Do not use in wet or damp locations;
this equipment emits UV-C radiation; Do not locate equipment in any
location allowing direct line-of-sight to vents, returns, or other duct openings
DO NOT use this unit with an extension cord
WARNING
Location for Protective Earth Line.
CAUTION
Wiring and installation of this unit must be done by a licensed HVAC
contractor or electrician; failure to do so will void warranty of the product
When the unit is installed in a roof mounted HVAC system, the unit must be
protected from the elements
Read this manual in its entirety before using your activTek INDUCT 750/2000.
Keep out of the reach of children.
Live voltage may be present
Disconnect power at the breaker or fuse panel before servicing unit; always follow OSHA lockout procedures
to prevent accidental exposure to electrical energy
If installed near a furnace or where emergency heat coils could raise the temperature inside the plenum, cycle
the AC unit through three full heating cycles assuring that the temperature never exceeds 200
°
F (93
°
C); the
ActivePure
®
Cell must not exceed 200
°
F (93
°
C)
If the unit is hard wired, be sure the power to the unit is o; always follow OHSA electrical lockout safety
requirements to prevent accidental release of energy during service or maintenance activities
Never attempt to check operation of the ActivePure
®
Cell(s) by direct observation; severe eye damage can
result; use the indicator lamps on the bottom of the ballast only