9
CHANGING THE ACTIVEPURE
®
CELL
1. Disconnect (unplug) power
cord from unit.
2. Remove the (4) thumb nuts.
3. Remove the unit from the
mounting plate.
Power Cord
5. Remove the used
ActivePure Cell from the base unit
and dispose of the bulb properly.
4. Remove the two thumb
screws holding the ActivePure
Cell.
6. Plug the new ActivePure Cell into
the base unit. Be sure Air Flow
/ Honeycomb Cell direction is
correct.
WARNING
• UV Light in operation; disconnect unit from power cord before servicing;
failure to follow warnings may result in severe eye damage
• If the unit is hard wired, be sure the power to the unit is o; always follow OHSA
electrical lockout safety requirements to prevent accidental release of energy
during service or maintenance activities
7. Secure with (2)thumb
screws.
8. Insert the unit into the
mounting plate.