17
Problem Possible Solution
Inaccurate
temperature or
humidity
Make sure both the display and 5-in-1 sensor are
placed away from any heat sources or vents
(see page 10).
Make sure both units are positioned away from
moisture sources (see page 10).
Make sure 5-in-1 sensor is mounted at least 5 ft (1.5
meters) off of the ground.
• Calibrate indoor and outdoor temperature and
humidity (see page 19).
No rainfall
• Check to ensure the rain gauge stabilizer (plastic tab)
has been removed from the bottom of the sensor (see
page 7).
• Clear debris, such as leaves, out of the rain collector
funnel and debris screen.
• Calibrate the Rain Gauge (see page 20).
Inaccurate wind
readings
What is wind reading being compared to? Pro
weather stations are typically mounted at 30 ft
(10 meters) high or more. Make sure to compare
data using a sensor positioned at the same mounting
height.
Check location of the sensor. Ensure it’s mounted
a minimum of 5 ft (1.5 meters) in the air with no
obstructions around it (within several feet).
Ensure wind cups are spinning freely. If they hesitate
or stop try lubricating with graphite powder or spray
lubricant.
Display screen
not working
Check that the power adapter is plugged into the
display and an electrical outlet.
Check that the batteries are installed correctly.
Batteries may need to be replaced.
Reset the display by pressing and holding the Reset
button, located in the battery compartment of the
display. Date and time will need to be entered after
a reset.
Troubleshooting