Central heating Solo P AquaSpeed P Excellence P
24 32 24 32 24 32
Max (intake) charge kW 24 30.5 24 30.5 24 30.5
Min (intake) charge kW 5.9 5.9 5.9 5.9 5.9 5.9
Max. output 80/60°C kW 23.3 29.3 23.3 29.3 23.3 29.3
Min. output 80/60°C kW 5.8 5.8 5.8 5.8 5.8 5.8
Efficiency (high power) 80/60°C % 97 96 97 96 97 96
Efficiency (low power) 80/60°C % 98 98 98 98 98 98
Efficiency (high power) 45/30°C % 105 104 105 104 105 104
Efficiency (low power) 45/30°C % 107 107 107 107 107 107
Flue gases
C0 emissions (high power / min.) mg/kWh ------
CO/Nox emissions (low power) mg/kWh ------
NOx classification - - - - - -
Flue gas temperature — high power 80/60°C °C 92 108 92 108 92 108
Flue gas temperature — high power 45/30°C °C -77-77-77
Mass flow rate of combustion products Kg/h 10.9 14.6 10.9 14.6 10.9 14.6
Maximum pressure drop of the flue gas system mbar 130 130 130 130 130 130
Max. length of the concentric flue gas system Ø 80 / Ø 125 m 20 20 20 20 20 20
Gas
Category (varies by country) I3P
G31 pressure (propane) mbar 30 / 37 / 50
G31 gas flow rate (propane) m
3
/h 0.98 1.3 0,98 1.3 0,98 1.3
CO2 (high power) G31 (with front panel closed) % CO2 10.5 10.5 10.5 10.5 10.5 10.5
CO2 (high power) G31 (with front panel open) % CO2 10.3 10.3 10.3 10.3 10.3 10.3
%CO2 (low power) G31 (with front panel closed) % CO2 10.4 10.4 10.4 10.4 10.4 10.4
Hydraulic parameters
Maximum operating temperature °C 90 90 90 90 90 90
Boiler water capacity l 881414 16 16
Domestic hot water circuit capacity L --0.90.9 54 54
Max. operating temperature CC bar 333333
Heat exchanger pressure drop (T = 20) mbar 131 193 131 193 131 193
Dimensions
Width mm 500 500 500 500 630 630
Depth mm 400 400 400 400 470 470
Depth (with backing) mm 520 520 520 520 - -
Height mm 900 900 900 900 900 900
Weight Kg ----8686
Electrical connection
Class IP 30 30 30 30 30 30
Supply voltage V/Hz 230~/50 230~/50 230~/50 230~/50 230~/50 230~/50
Electrical power A 0.8 0.8 1.2 1.2 1.2 1.2
7
TECHNICAL DATA
UK
PROPANE MODEL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ACV PRESTIGE Series and is the answer not in the manual?

ACV PRESTIGE Series Specifications

General IconGeneral
Fuel TypeNatural Gas
InstallationWall-mounted
Heat Exchanger MaterialStainless Steel
Boiler TypeCondensing
Ignition TypeElectronic
Control SystemDigital
Heating CapacityVariable, based on model
Temperature Range30°C to 85°C
Modulation Range1:10