SLE - SLE Plus: A1007847 - 661Y2100 • D
Technical Characteristics
DOMESTIC HOT WATER PERFORMANCES
DHW performance :
Heating source = External boiler
connected to tank *
Smart E
130
Smart E
160
Smart E /
Smart E
Plus
210
Smart E /
Smart E
Plus
240
Smart E /
Smart E
Plus
300
Peak flow at
40°C [∆T = 30K]
L/10' 236 321 406 547 800
60°C [∆T = 50K]
L/10' 117 161 209 272 370
Constant flow at
40°C [∆T = 30K]
L/h 658 890 1,132 1,527 2,100
60°C [∆T = 50K]
L/h 320 465 576 769 970
Peak flow 1
st
hour at
40°C [∆T = 30K]
L/60' 784 1,063 1,349 1,820 2,360
60°C [∆T = 50K]
L/60' 384 549 689 913 1,100
Maximum absorbed power kW 23 31 39 53 68
* Conditions : Primary circuit temperature : 85°C, water intake temperature : 10°C
MAIN CHARACTERISTICS
Main Characteristics
Smart E
130
Smart E
160
Smart E /
Smart E
Plus
210
Smart E /
Smart E
Plus
240
Smart E /
Smart E
Plus
300
Total capacity L 130 161 203 242 293
Primary capacity L 55 62 77 78 93
DHW capacity L 75 99 126 164 200
Primary pressure drop* mbar 26.8 26.8 41.6 47.3 52.4
Heating surface area 1.03 1.26 1.54 1.94 2.29
Max Design Pressure* bar 10 10 10 10 10
Reheat Performance - Primary
Heating Power Input*
kW 18.4 24.7 32.2 39.2 44.6
Primary flow rate (to achieve
Reheat Performance) *
L/sec. 0.7 0.7 1.25 1.25 1.25
Reheat time*
min 10 10 9 9 9
Approx. heating time (with
optional heating element)
- From 10 to 65°C
3 kW min 80 100 150 180 330
6 kW min 40 50 75 90 165
Standing Heat Loss*
kWh/24h 0.96 1.13 1.3 1.42 1.66
W 40 47 54 59 69
Empty Weight Kg 45 54 66 76 87
* According to EN12897:2016