EasyManua.ls Logo

ACV Smart E 130 - Technical Characteristics; Dimensions; Maximum Operating Conditions

ACV Smart E 130
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SLE - SLE Plus: A1007847 - 661Y2100 • D
T C
DIMENSIONS
Smart E
130
Smart E
160
Smart E
210
Smart E
240
Smart E
300
Smart E
Plus
210
Smart E
Plus
240
Smart E
Plus
300
A (mm)
1,025 1,225 1,495 1,740 2,045 1,495 1,740 2050
B (mm)
765 960 1,230 1,485 1,780 1,235 1,480 1785
C (mm)
240 240 240 240 235 240 235 235
D (mm)
240 240 290 290 405 260 260 340
E (mm)
935 920 1280
F (mm)
430 430 525
G (mm)
320 320 405 320 320 380
H (mm)
240 240 230 240 240 235
Smart E
130
Smart E
160
Smart E /
Smart E
Plus
210
Smart E /
Smart E
Plus
240
Smart E /
Smart E
Plus
300
Max. operating pressure - primary bar 3 3 3 3 3
Max. operating pressure - DHW bar 8.6 8.6 8.6 8.6 8.6
Supply pressure (DHW circuit) bar 6 6 6 6 6
Maximum temperature - heating side °C 90 90 90 90 90
Maximum temperature - DHW side °C 80 80 80 80 80
Water quality
Chlorides < 150 mg/L
6 ≤ pH ≤ 8
If hardness > 20°fH, water softener recom-
mended.
MAXIMUM OPERATING CONDITIONS
9
EN
A
B
C
D
F
G
H
G
E
360
150
565

Related product manuals