EasyManua.ls Logo

ADDER CCS-PRO - Page 23

ADDER CCS-PRO
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
INSTALLATIONCONFIGURATIONOPERATION
FURTHER
INFORMATION
INDEX
3 Double-click on each screen representation to set the screen resolution and,
optionally, add a screen name and/or congure an LED monitor indicator:
See also Additional Free-
Flow operations and settings
The screen resolutions are not critical but they enable the CCS-PRO4 switch to
accurately map the movement of the mouse onto corresponding movements of the
pointer across the screens. The screen names, if used, are not downloaded to the
CCS-PRO4 switch.
If you need to congure an LED monitor indicator, click the LED Setup tab. Please see
Conguring LED monitor indicators for details.
4 When the screen map is complete and accurately matches the true layout of the
display screens, choose File > Save to store a copy of the layout. The layout will be
stored as a ‘Free-Flow Cong le’ with the extension: .ffc
5 To send the conguration, select Congure > Send Layout to Switch.
If the download is successful, the screen representations will briey turn grey and
the upper four indicators on the CCS-PRO4 switch will begin to scroll across (they
will continue to do this while Free-Flow mode is enabled).
If the download is unsuccessful, a message dialog will explain that it is ‘Unable to
communicate with the device’. Check the connection and the settings mentioned in
the section Installing the standard conguration application.

Related product manuals