ADEMCO Vista-10 Specifications

General IconGeneral
KeypadsUp to 8
Power Supply16.5VAC, 25VA Transformer
Outputs2 programmable outputs
Partitions1
CommunicationCellular
Battery Backup12VDC, 4AH
TypeWired Security System

Summary

System Overview

Burglary Protection Modes

Details arming modes (STAY, AWAY, INSTANT, MAXIMUM) and CHIME mode.

Fire Protection Functionality

Explains the 24-hour fire protection and directs to the FIRE ALARM SYSTEM section.

Alarm Occurrence and Silencing

Describes what happens when an alarm occurs and how to stop it.

Functions of the Console

OFF Key Operation

Explains how the OFF key disarms the system, silences alarms, and clears displays.

AWAY Key Operation

Describes arming the entire system (interior and perimeter).

STAY Key Operation

Describes arming the perimeter only, allowing movement inside.

MAXIMUM Key Operation

Explains arming the entire system without an entry delay.

TEST Key Operation

Explains testing the system and alarm sounder.

BYPASS Key Operation

Explains removing individual zones from monitoring.

INSTANT Key Operation

Describes arming perimeter without entry delay.

Emergency (Panic) Keys

Discusses individual keys for emergency functions.

Security Codes

Master Code and User Codes

Explains the Master code and temporary user codes for system functions.

Duress Code Functionality

Describes a code used under threat to silently notify the central station.

Quick Arming Feature

Explains using the '#' key for quick arming without a code.

Managing User Codes

Provides step-by-step instructions for managing user codes.

Entry and Exit Delays

General Entry/Exit Delay Information

Explains preset exit and entry delays for arming/disarming.

Checking for Open Zones

Using the * READY Key

Explains how to check for open zones before arming.

Bypassing Protection Zones

Using the 6 BYPASS Key

Explains how to bypass specific zones before arming.

Quick Bypass Feature

Explains bypassing all open zones without entering numbers individually.

Arming Perimeter Only with Entry Delay On

Using the 3 STAY Key

Explains how to arm the perimeter while allowing entry/exit through a specific door.

Arming Perimeter Only with Entry Delay Off

Using the 7 INSTANT Key

Explains arming perimeter without entry delay, for when no one is expected to enter.

Arming All Protection with Entry Delay On

Using the 2 AWAY Key

Explains arming all zones (interior and perimeter) with exit/entry delay.

Arming All Protection with Entry Delay Off

Using the 4 MAXIMUM Key

Explains arming all zones without entry delay, for vacant premises.

Disarming the System and Silencing Alarms

System Disarming Procedure

Explains how to disarm the system using the OFF key.

Silence Burglary Alarm

Details silencing burglary alarms and clearing memory.

Silence Fire Alarm

Explains silencing fire alarms and clearing memory.

Panic Keys

Activating Panic Keys

Explains how to manually activate emergency functions using keys.

Testing the System

Trouble Conditions

Interpreting Check and Battery Displays

Explains the meaning of "CHECK" and "BATTERY" displays and how to clear them.

Power Failure Diagnosis

Describes what happens during a power failure and how to diagnose.

Fire Alarm System (If Installed)

Fire Alarm Emergency Procedures

Provides steps to take in case of a fire alarm.

Silencing Fire Alarms Procedure

Details how to silence fire alarms and clear the console display.

Emergency Evacuation

Steps for Emergency Evacuation Planning

Provides steps for planning and practicing an escape plan in case of fire.

Quick Guide to Alarm System Functions

Arm System Function

How to arm the system in various modes.

Bypass Zone(s) Function

How to bypass specific zones.

Silence Sounders Function

How to silence burglary and fire alarms.

Disarm System Function

How to disarm the system.

Summary of Audible/Visual Notification (Alpha Consoles)

Summary of Audible/Visual Notification (Fixed-Word Consoles)

Protection Zones List

Alarm System Limitations Warning