ADJ Products, LLC - www.adj.com - Flat Par TW12 User Manual Page 10
Flat Par TW12 Operating Instructions
Default Running Mode:
1. This is a default running mode. When this mode is activated, all modes will return to their default
settings.
2. Plug the xture in and press the MODE button until “dXX” is displayed. “XX” represents either
“on” or “oFF”.
3. Press the SET UP button until “dEFA” is displayed.
4. Press the UP and DOWN buttons simultaneously. Press the MODE button to exit.
ADJ LED RC3:
This function is used to activate and deactivate the ADJ LED RC3 (Remote Control). When this func-
tion is activated you can control the xture using the ADJ LED RC3. Please see the ADJ LED RC3
section of this manual for controls and functions.
1. Plug the xture in and press the MODE button until “dXX” is displayed. “XX” represents either
“on” or “oFF”.
2. Press the SET UP button until “IrXX” is displayed. “XX” represents either “on” or “oFF”.
3. Press the UP or DOWN buttons to either activate the remote function (On) or deactivate it (O).
DMX State:
This mode is used to dene how the xture will behave when the DMX signal is lost or interrupted. It
also denes the operating mode that the unit to return to when power is rst applied.
1. Press the MODE button until the DMX address is displayed.
2. Press the SET UP button until “No-X” is displayed. “X” represents a number between 0-2.
3. Use the UP or DOWN buttons to scroll to the operating mode you would like the unit to start up
in when power is applied or the DMX signal is lost.
“N0-0” (BLACKOUT) - If the DMX signal is lost or power is applied, the unit will automatically
go into stand by mode.
“N0-1” (HOLD) - If the DMX signal is lost the xture will stay in the last DMX set up. If power
is applied and this mode is set, the unit will automatically go into the last DMX set up.
“N0-2” (FADE PROGRAM) - If the DMX signal is lost or power is applied, the unit will auto-
matically run the fade program.
Dimmer Curve:
This is used to set the dimmer curve used with DMX mode. See the Dimmer Curve Chart section of
this manual for more information.
1. Plug the xture in and press the MODE button until the DMX address is displayed.
2. Press the ENTER button until “dr-X” is displayed. “X” represents the current dimming mode.
3. Use the UP and DOWN buttons to nd your desired dimmer curve. Press SET UP when you are
nished.
dr-0 - Standard
dr-1 - Stage
dr-2 - TV
dr-3 - Architectural
dr-4 - Theater

Other manuals for ADJ FLAT PAR TW12