6
PAGER OPTIONS 160-172
160
PAGER 1 PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
161
PAGER 1 CHARACTERS
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
162
PAGER 1 REPORTING OPTIONS
Part. 1 Part. 2 common
[0,0,0]
For each partition, select from the following options:
0 = no reports sent
1 = Open/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and open/closes for all users
12 =Alarms / troubles for zones entered in zone list 9
13 =Alarms / troubles for zones entered in zone list 9,
and open\closes for all users
163
PAGER 2 PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
164
PAGER 2 CHARACTERS
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
165
PAGER 2 REPORTING OPTIONS
[0,0,0]
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each
partition (use zone list 10 if using options 12 or 13).
166
PAGER 3 PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
167
PAGER 3 CHARACTERS
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
168
PAGER 3 REPORTING OPTIONS
0,0,0]
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each
partition (use zone list 11 if using options 12 or 13).
169
PAGER 4 PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
170
PAGER 4 CHARACTERS
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
171
PAGER 4 REPORTING OPTIONS
[0,0,0]
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each
partition (use zone list 12 if using options 12 or 13).
172
PAGER DELAY OPTION FOR ALARMS
[3]
0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes
This delay is for ALL pagers in the system.
NOTE:
The delay does not reset for new alarms
occurring while an existing pager delay is in progress.
REPORTING OPTIONS 173-177
173
RF REPORTING OPTIONS
[3]
0 = disable all options
1 = RF Tamper reports during disarm
2 = RF button types send low battery
8 = RF low battery reports delayed (delayed 28 days)
Example:
Entering “10” (8 + 2) enables button-type
transmitters to send low battery reports and delay all
reports for 28 days. UL: see Inst. Instr. for requirements
174
CLEAN ME REPORTING OPTIONS
(for ESL smoke detectors)
[0]
0 = disable; 1 = Clean Me signal reports;
2 = Clean Me reports, 28-day enabled.
Note:
If Clean Me is enabled, you must enter “3” in
field
56 programming for zone 1 response time.
175
UP AND ABOUT TIME
[0]
0 = none, 1 = 1 hour, 2 = 2 hours,… 15 = 15 hours
(hourly increments)
176
LACK OF USAGE OPTION
[0]
1–15 = number of weeks selected (1 week increments)
If panel is not armed within the time period selected, a
report will be sent to the central station.

Other manuals for ADT Safewatch Pro 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Safewatch Pro 3000 and is the answer not in the manual?

ADT Safewatch Pro 3000 Specifications

General IconGeneral
KeypadsSupports multiple keypads
CommunicationLandline, cellular
Remote AccessVia ADT Pulse (if subscribed)
TypeWired
Power Supplybattery backup
CompatibilityADT Monitoring Services
SensorsDoor/Window, Motion
InstallationProfessional
Backup BatteryYes

Related product manuals