PIDs Menu
Item Function Options
Transport
Stream ID
Sets the Transport Stream ID in PAT and other
tables in the egress transport stream.
Configure this value in Hex.
0x0001 - 0x1FFE
PMT PID PMT PID refers to the PID of the Program Map Table
(PMT). Program Map Tables are used to describe
the properties of a single program.
user-defined using
the numeric keypad
PCR PID Programs periodically provide a Program Clock
Reference, or PCR, on one of the PIDs in the
program. This is also known as the master clock.
The PCR PID identifies the packets which contain
PCR adaptation fields.
user-defined using
the numeric keypad
Video PID Video PID identifies packets containing the video
Packetized Elementary Stream data.
user-defined using
the numeric keypad
Audio PID
1-8
Identify packets containing audio content for the
specified channels
user-defined using
the numeric keypad
Teletext PID Teletext PID identify packets containing teletext
information.
user-defined using
the numeric keypad
VITC PID Sets the Program ID (PID) for the ANC (H & V).
ANC Data captured from HD-SDI source is carried
per SMPTE-2038. Typically this is used to carry
VITC. If VITC and LTC are carried concurrently, LTC
is dropped.
user-defined using
the numeric keypad
AMOL PID Automated Measurement of Line Ups; identifies
packet which contains AMOL (NTSC) information
Only applies to 525 line (NTSC) video.
user-defined using
the numeric keypad
Splice PID Splice PID is used for Cable Labs SCTE 35 Splice
Point identification.
user-defined using
the numeric keypad

Table of Contents