DESCRIPTION
TheTotalAccess
®
361and362SingleFamilyUnit(SFU)OpticalNetwork
Terminations(ONTs)areGigabitPassiveOpticalNetwork(GPON)ONTs
withRFOverlay.TheTotalAccess361SFUONThas2POTS,and1
GigabitEthernetinterface.TheTotalAccess362has2POTS,and2Gigabit
Ethernetinterfaces.Thefigureabove
illustratestheSFUONTinner
enclosure.GPONtechnologyprovidesaconsistentandcommon
approachtoadvancingthepubliccommunicationsnetworkusing:
TraditionaltelephoneserviceisPlainOldTelephoneService(POTS)
Highspeeddataservices
Videoservices
TheGPONnetworkconsistsofanOpticalLineTerminal(OLT)locatedat
thecentralofficeandOpticalNetworkTerminals(ONTs)locatedatthe
customerspremises.BetweenthemliestheOpticalDistributionNetwork
(ODN)consistingoffibersandpassivesplittersorcouplers.
Inordertoallowforthetransmissionof
downstreamandupstreamtraffic
ononesinglefiber,differentwavelengthsareusedforeachdirection.
Downstreamtrafficuses1490nm,whileupstreamtrafficiscarriedon
1310nm.ForoverlayRFTVdistribution,aseconddownstream
wavelengthof1550nmisused.
RF
Connection
RF Drop
Surface
Mounting
Hole
Surface Mounting
Hole
Hinge
Hinge
Security
Screw
Two-screw
Terminal
Bridges
Ethernet
Connections
Fiber Optic
Cable
Ground
Power
Ethernet Drop
POTS Drop
Ground and Power
Drop Callout
Ground Drop
Fiber Drop
RING
TIP
RING
TIP
FXS 0/1
FXS 0/2
ETH 0/1
ETH 0/2
POTS 1
POTS 2
ETH 1
ETH 2
TOTAL ACCESS 362 ONT
1187712G1
12V , 1A
CLEI
TIP RING
TEL. NUMBER
TIP RING
TIP RING
NETWORK STATUS
POTS 2
POTS 1
TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
any working telephone into that jack.
If the telephone works, there is a problem inside the house.
If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.
TIP
RING
ETH 0/1
ETH 0/2
Total Access 300 Series
GigE SFU GPON ONTs
with RF Overlay
ThisJobAidcoverstheelectronicsmodules(SFUONT)andhousings
listedinthefollowingtable:
NOTE
TheTotalAccess361/362SFUONTsareonlyintendedtobeusedwiththe
CorningSystemsModelFNINGseriesoutdoorNIDhousing.
FRONT PANEL LEDS
INSTALLATION
NOTE
RefertotheTotalAccess300GigESFUONTsInstallationGuide
(P/N6418771XGX5)forcompleteinformationoninstallingtheseunits.
AfterunpackingtheSFUONT,inspectitfordamage.Ifdamageisnoted,
fileaclaimwiththecarrierandthencontactADTRAN.Formoreinfor
mation,refertothewarranty.
Total Access 361 Description
1187711G1 TotalAccess361SFUElectronicsModule
4187711G12 TotalAccess361withSpliceHousing
4187711G13 TotalAccess361withOptiTapHousing
Total Access 362 Description
1187712G1 TotalAccess362SFUElectronicsModule
4187712G12 TotalAccess362withSpliceHousing
4187712G13 TotalAccess362withOptiTapHousing
Total Access SFU
Housings
Description
1187770G1 TotalAccessONTSpliceHousing
1187771G1 TotalAccessONTwithOptiTapHousing
Label Status Description
POWER
{
z
Off
Green
Nopower
PowerisOn
NETWORK
STATUS
{
z
z
z
Off
Green
Yellow
Red
AdministrativelyShutDown
Normal
Testinprogress
FaultCondition
POTS
1 and 2
{
z
2
z
z
Off
Green
GreenFlashing
Yellow
Red
AdministrativelyShutDown
OffHook
Ringing
Testmode
Fault
ETH 1and 2
{
z
4
Off
Green
YellowFlashing
Linkisdown:noactivityor
AdministrativelyShutDown
10/100/1000Linkisup
TXorRXactivity
Product P/N: 418771XGX
Issue Date: March 2010
Document P/N: 6418771XGX-22B

Questions and Answers

Overview

The ADTRAN Total Access 300 Series GigE SFU GPON ONTs with RF Overlay are Single Family Unit (SFU) Optical Network Terminations (ONTs) designed for Gigabit Passive Optical Network (GPON) applications with an RF Overlay. These devices provide a consistent and common approach to advancing public communications networks by supporting traditional telephone service (POTS), high-speed data services, and video services.

Function Description:

The SFU ONTs act as the customer premises component of a GPON network, connecting to an Optical Line Terminal (OLT) at the central office via an Optical Distribution Network (ODN) of fibers and passive splitters/couplers. They facilitate the transmission of downstream and upstream traffic on a single fiber using different wavelengths: 1490 nm for downstream, 1310 nm for upstream, and an additional 1550 nm for overlay RF TV distribution.

The Total Access 361 SFU ONT features 2 POTS interfaces and 1 Gigabit Ethernet interface. The Total Access 362 SFU ONT offers 2 POTS interfaces and 2 Gigabit Ethernet interfaces. Both models are designed to be housed in Corning Systems Model FNI-NG series outdoor NID housings.

Important Technical Specifications:

  • Operational Temperature Range: -40°C to +65°C
  • Storage Temperature Range: -40°C to +85°C
  • Voltage Range: 10.5 to 15 VDC
  • Maximum Current: 1.5 Amps
  • Relative Humidity: 95%, noncondensing
  • Dimensions: 9.7"W x 12"H x 4"D
  • Weight: 3 lbs 0.8 oz (enclosure and electronics module)
  • Operating Altitude Range: -197 feet (-60 meters) to 13000 feet (3962 meters), with a derating of 1°C/1000 feet (3.3°C/km) for ambient temperature.
  • Ethernet Ports:
    • Total Access 361: ETH 1 (Data and/or Video)
    • Total Access 362: ETH 1, ETH 2 (Data and/or Video)
  • Compliance: NRTL Listed to UL safety standards, meets or exceeds NEBS and Telcordia GR-63-CORE requirements.
  • FCC Compliance: Complies with Part 15 of FCC rules, subject to not causing harmful interference and accepting any interference received.
  • Laser Safety: Contains a Class 1 Laser Module compliant with 21 CFR 1040.10 and 1040.11.
  • Grounding: Requires connection to a known, reliable earth ground using a 6 AWG copper ground conductor, as part of a Common Bonding Network (CBN).
  • Power Input: Designed to operate with nominal 12 VDC (minimum 10.5 VDC) and will not be damaged by steady state voltages between 10.5 VDC and 15.0 VDC.

Usage Features:

  • Installation: The enclosure is designed for vertical surface mounting. The electronics module swings open on hinges for easy access during installation.
  • Ground Connection: A #6 solid copper ground wire is routed through a rubber grommet to a ground bar, then to the AC power ground system of the customer premises.
  • Power/Alarm Connections: Utilizes a 7-conductor Euro-style Power/Alarm connector for connections from a UPS. Pin-out information is provided for LOW BAT, BAT MIS, REP BAT, ON BAT, SIG RTN, 12V RTN, and +12VDC.
  • OptiTap Fiber Drop Cable Routing: The OptiTap fiber drop is routed through the same rubber grommet channel as the ground cable, ensuring the fiber is not pinched when the electronics module is closed.
  • SC/APC Optical Connection: Fiber is routed through a grommet entrance and connected to the SC/APC optical connection, with care taken to avoid bends less than 30 mm (1.2 inches) radius.
  • Local Power Source Wiring: The SFU ONT must be powered by a UL Listed Power Supply suitable for LPS Levels, as recommended by the power supply manufacturer.
  • UPS Installation: The Uninterruptible Power Source (UPS, P/N 1187730G1) cable connects to the SFU ONT's Power/Alarm connector.
  • POTS Connection: Telephone service can be connected using two-screw terminal bridges or directly to RJ-11 jacks. RJ-11 jacks also serve as diagnostic test points, isolating subscriber service for fault isolation.
  • RF Connection: The RF cable is routed through a large grommet and attached to the RF connector on the bottom of the electronics module.
  • Ethernet Connection: Supports up to 1 Gigabit operation (10/100/1000) using CAT-6 cable and RJ-45 plugs.
  • Front Panel LEDs:
    • POWER: Off (No power), Green (Power is On).
    • NETWORK STATUS: Off (Administratively Shut Down), Green (Normal), Yellow (Test in progress), Red (Fault Condition).
    • POTS 1 and 2: Off (Administratively Shut Down), Green (Off Hook), Green Flashing (Ringing), Yellow (Test mode), Red (Fault).
    • ETH 1 and 2: Off (Link is down: no activity or Administratively Shut Down), Green (10/100/1000 Link is up), Yellow Flashing (TX or RX activity).

Maintenance Features:

  • No Routine Hardware Maintenance: The SFU ONT does not require routine hardware maintenance for normal operation.
  • Repair Services: ADTRAN does not recommend field repairs. Defective units should be returned to ADTRAN for repair services.
  • Software Support: Field support for software is provided through upgrade facilities.
  • ESD Precautions: When handling modules, an antistatic discharge wrist strap should be worn, and modules should be placed in antistatic packing material.

ADTRAN 418771 G Series Specifications

General IconGeneral
BrandADTRAN
Model418771 G Series
CategoryNetwork Hardware
LanguageEnglish