DESCRIPTION
This Quick Start provides instructions for the installation of the
GPON 452/454 Optical Network Termination (ONT) units (see part
numbers listed below). The ONTs have POTS and GigE interfaces
that provide triple-play services. The GPON 452 ONT has two
POTS ports and two Gigabit-Ethernet ports; the GPON 454 ONT
has four POTS ports and four Gigabit-Ethernet ports.
The ONT is to be enclosed in a weather-hardened Network Inter-
face Device (NID) which mounts to the exterior of a building. The
figure below illustrates the ONT in the context of the NID with the
access door of the NID removed.
g NOTE
NID Enclosure is shown for reference only.
The ONT is a Class 1 Laser Product.
ONT Part Number
ADTRAN ONT GPON 452 Exterior Wall Mount
Outdoor ONT
1287802F1
ADTRAN ONT GPON 454 Exterior Wall Mount
Outdoor ONT
1287803F1
RING
POTS1 POTS2 POTS3 POTS4
TIP
TELCO ACCESS
ETH 2 ETH 1ETH 4 ETH 3
GPON 454 1287803F1
12V , 1.25A
TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
any working telephone into that jack.
If the telephone works, there is a problem inside the house.
If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.
This device is intended to be attached to a receiver that is not used to
receive over-the-air broadcast signals. Connection of this device in any
other fashion may cause harmful interference to radio communications
ans is in violation of the FCC Rules, part 15.
CLEI
TEL. NUMBER
PWR
GPON
POTS1
POTS2
POTS3
POTS4
CLASS 1 LASER
PRODUCT
INSTALLATION
This section explains how to install the NID, ground the NID, route
and attach the incoming Fiber, and install the ONT in the NID.
There is also a section on connecting POTS and Ethernet services.
After unpacking the ONT, inspect it for damage. If damage is noted,
file a claim with the carrier and then contact ADTRAN. For more
information, refer to the warranty.
f WARNING!
Read all warnings and cautions before installing or servicing this
equipment.
Refer to the national, state and local electrical codes for the
requirements for power and grounding wiring methods.
The protective earth (PE) grounding wire for this product mu
st
be 6 A
WG (13.3 mm
2
). The connector must be a suitable,
ap
proved ground wire connector.
This equipment must be serviced by authorized servic
e
pe
rsonnel only. All repair procedures are detailed to allow
sub-assembly repairs ONLY. Authorized service personnel
should not attempt component level repairs or circuit
modifications to the printed circuit board. Improper repairs ca
n
crea
te a safety hazard.
Required Tools and Supplies
In addition to standard technician tools, you must have the following
tools for this installation:
Carpenter’s level
3/32 inch screw driver for connecting ONT power
5/32 inch hex tamper proof bit
Two #10 screws (Max. Head Diameter 0.385”) and appropria
te
wa
ll anchors for mounting the NID
RJ-45 crimper
A telephony/data communication test set
Assorted tie wraps for securing cabling and wiring
Up to four RJ-45 plugs
For fiber optic connections, you must have the following tools:
PON power meter with wavelength filtering
Fiberscope or videoscope
Fiber optics Fusion splicing tools
Fiber connector cleaning tool
SC/APC fiber connector
Optical Network Terminal
GPON 452/454
Exterior Wall Mount ONT
May 2020
61287802F1-13F
1287802F1

Other manuals for ADTRAN GPON 452

Questions and Answers

  • J
    jenkinshollyAug 1, 2025
    Why is the NETWORK STATUS LED red on my ADTRAN Network Hardware?
    • K
      Kaitlyn EatonAug 1, 2025
      If the NETWORK STATUS LED on your ADTRAN Network Hardware is red, there may be a software configuration issue between the OLT and the SFU ONT. Contact the Central Office to resolve this.
  • J
    James WilsonAug 6, 2025
    How to fix ADTRAN Network Hardware when NETWORK STATUS LED is off?
    • M
      melissascottAug 6, 2025
      If the NETWORK STATUS LED is off on your ADTRAN Network Hardware, check all fiber connections. Ensure all connections are clean and tight.
  • Y
    Yolanda StewartAug 10, 2025
    What to do if ADTRAN GPON 452 Network Hardware LEDs are normal but problems still exist?
    • N
      navarrocraigAug 10, 2025
      If the LEDs on your ADTRAN Network Hardware are normal but you're still experiencing issues, here are a few things you can check: * First, see if other ONTs installed in the PON are working correctly. If other ONTs are working, the problem is likely with your current ONT. If none are working, the issue might be with the PON or OLT. * If the problem seems random, inspect the common mounting platform for loose or broken connections. Also, ensure all optical connections are clean and tight. * If the problem is consistent, disconnect the Customer Provided Equipment (CPE) wiring and perform Ethernet tests. Verify the OLT can run and pass the loop-back tests for the Ethernet port.
  • Y
    Yolanda NorrisAug 14, 2025
    What to do if LEDs on ADTRAN GPON 452 Network Hardware SFU ONT cycle continuously?
    • J
      Jessica SmithAug 15, 2025
      If the LEDs on the front of your ADTRAN Network Hardware SFU ONT are cycling continuously, try the following steps: 1. Try a different SFU ONT. 2. Make sure the power supply is functioning correctly.
  • J
    Jason FerrellAug 18, 2025
    What to do if Downstream Optical Signal Level is not within range on ADTRAN GPON 452?
    • M
      Michael OrrAug 19, 2025
      If the Downstream Optical Signal Level is not within the correct range on your ADTRAN Network Hardware, you should perform testing and verification further up the network, towards the OLT, to find the cause of the optical signal level differences.
  • L
    Lori FullerAug 23, 2025
    What to do if Upstream Optical Signal Level is not within range on ADTRAN GPON 452?
    • A
      Amanda McdonaldAug 23, 2025
      If the Upstream Optical Signal Level is not within the correct range on your ADTRAN Network Hardware, first verify the provisioning of the ONT at the OLT. If the problem persists after verifying the provisioning, replace the ONT.
  • A
    Alex WalterAug 27, 2025
    What does it mean if NETWORK STATUS LED continually flashes Yellow on ADTRAN GPON 452?
    • M
      Michael TaylorAug 27, 2025
      If the NETWORK STATUS LED on your ADTRAN Network Hardware continually flashes yellow, contact the Central Office.

Summary

Description of GPON 452;454 ONT

Installation Process Overview

Important Safety Warnings

Read all warnings and cautions before installing or servicing this equipment.

Required Tools and Supplies

Lists tools and supplies needed for installation, including specific items for fiber optics.

Installation Steps

NID Port Identification

Identifies the four input ports on the NID for service entry.

Mount the NID Enclosure

Provides instructions and considerations for mounting the NID enclosure.

Ground the NID

Details the steps for installing the ground connection for the NID.

Route the Fiber Connection

OptiTap NID Fiber Connection

Instructions for installing fiber connection using the Optical Connector.

Fiber Splice SC;APC Bulkhead NID

Instructions for installing fiber connection using the bulkhead connector.

Install the ONT

Connect Power and Alarm

Install a Local Power Source

Connect Subscriber Services

Connect POTS Lines

Steps for terminating POTS lines and connecting to the ONT.

Connect Ethernet to ONT

Steps for connecting subscriber Ethernet wires to the ONT.

ONT LED Status Indicators

Registration ID Configuration

Set Registration ID using Linemans Handset

Procedure to set the Registration ID using a DTMF keypad.

Product Specifications

Electrical Specifications

Details the electrical input power and consumption specifications.

Optical Specifications

Lists the optical transmit and receive power, sensitivity, and wavelength specs.

Physical Specifications

Provides physical dimensions and weight of the NID and ONT.

Environmental Specifications

Outlines operational and storage temperature, and humidity ranges.

Maintenance Recommendations

Safety and Regulatory Information

ADTRAN GPON 452 Specifications

General IconGeneral
GPON Ports1
GE Ethernet Ports4
GigE Ports4
POTS Ports2
Power Supply12 VDC
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C