1
DESCRIPTION
This Job Aid supports three Active Ethernet Single Family Unit (SFU) Optical
Network Terminal (ONTs) that can be installed in four different configurations
at the subscriber’s residence.
■ Outdoor Installation, using ONT 1287704G1
■ Indoor Installation in an unrestricted location, using ONT 1287704G1 and
Mounting Bracket 1187777G1
■ Indoor Installation, using ONT 1287737G1
■ Indoor Installation, using ONT 1287737G2
The following table lists the supported equipment.
The following illustration is typical of an “Outdoor” ONT.
The illustration below is typical of an unrestricted access location ONT.
Description Part Number CLEI
Total Access 354E Active Ethernet SFU
ONT
1287704G1 BVMBD10F _ _
Total Access 324E Indoor Active Ether-
net ONT
1287737G1 BVMBE10F _ _
Total Access 324E Indoor Active Ether-
net ONT with UPS
1287737G2 BVMBF10F _ _
Total Access 3XX Mounting Bracket 1187777G1 NA
Surface
Mounting
Hole
Surface Mounting
Hole
Hinge
Hinge
Security
Screw
Two-screw
Terminal
Bridges
Ethernet
Connections
Fiber Optic
Cable
Ground
Power
Ethernet Drop
POTS Drop
Ground and
PowerDrop
Callout
Ground Drop
Fiber Drop
RING
TIP
RING
TIP
FXS 0/1
FXS 0/2
ETH 0/1
ETH 0/2
TIP
RING
POTS 2
POTS 1
TELCO ACCESS
ETH 1 ETH 2
ETH 3
ETH 4
TOTAL ACCESS 354E
1287704G1
12V , 1.0A
POWER
NETWORK STATUS
TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
any working telephone into that jack.
If the telephone works, there is a problem inside the house.
If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.
CLEI
TEL. NUMBER
TIP/RING
POTS 1
POTS 2
Total Access 300 Series
Active Ethernet
Single Family Unit ONT
For installation in an Unrestricted Access location, refer to the Total Access 300
Series Active Ethernet Single Family Unit ONT Installation and Maintenance Guide
(P/N 612877AEONT-5).
The illustration below is typical of an “Indoor” ONT. The difference between
the two versions of the Total Access 324E ONT is the power source. Part
number 1287737G1 uses a 3-pin 12 Volt AC Adaptor, and the 1287737G2 uses
an Uninterruptible Power Source (UPS). The following illustration represents
the 1287737G2.
TIP/RING
Ground Wire
DO NOT Use Terminal Bridges for POTS Connections.
TELCO ACCESS
ETH 1 ETH 2
TOTAL ACCESS 354E
1287704G1
12V , 1.5A
POWER
NETWORK STATUS
TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
any working telephone into that jack.
If the telephone works, there is a problem inside the house.
If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.
CLEI
TEL. NUMBER
POTS 1
POTS 2
POTS 1
POTS 2
ETH 3 ETH 4
TIP/RING
Tie Wrap Point
Power
Tie Wrap Point
Fiber
PHONE 1
PHONE 2
NET
1
23
ETHERNET
4
LOW BAT
BAT MIS
REP BAT
ON BAT
SIG RET
12V RET
+12V
Total Access 324E
PHONE
PWR
NET
1
2
1
2
3
4
ETH
Issue Date: March 2015
Document P/N: 612877AEONT-22B
The following related online documents and resources provide additional information for this product:
Total Access 300 Series Active Ethernet Single Family Unit Installation and Maintenance Guide
Total Access 5000 Series Fiber to the Premises Deployment Guide
Total Access 5000/5006 Engineering Guide
Documentation for ADTRAN Carrier Networks products is
available for viewing and download directly from the
ADTRAN Support Community website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including
customized training and courses taught at our facilities or at
customer sites.
For inquiries, go to: http://adtran.com/training