1
jobAid
DESCRIPTION
This Job Aid covers two types of Single Family Unit (SFU) Optical
Network Terminations (ONTs): Outside ONTs (ONTs installed on the
outside of a customer’s residence--see Items 1 to 6 in the table below), and
Indoor ONTs (ONTs installed inside a customer’s residence--see Items 7
to 9 in the table below). This Job Aid supports the ONTs listed in the
following table.
The SFU ONT is part of a Gigabit Passive Optical Network (GPON). The
Total Access 300 Series ONT provides POTS and Ethernet interfaces, and
depending on the model, an RF interface.
To allow for the transmission of downstream and upstream traffic on one
single fiber, different wavelengths are used for each direction.
Downstream traffic uses 1490 nm (digital), while upstream traffic is
carried on 1310 nm. For RF TV distribution, a second downstream
wavelength of 1550 nm is used (video). Minimum and Maximum power
levels for RF Units is -8 dBm and +2 dBm respectively.
NOTE
The ONT in Figure 1 is a Total Access 362R 2nd Generation 2 POTS/2
Ethernet and one RF Return ONT. This typifies ONTs installed in a
Corning Network Interface Device (NID) housing. Figure 2 displays the
front and back of a Total Access 334 Single Family Unit with a UPS
connection. This model typifies ONTs installed inside the customer
premises.
Item Description Part Number CLEI
Outdoor ONTs
1 Total Access 351 2nd Generation 2
POTS/1 Ethernet SFU ONT
1287701G1 BVL3AP8D_ _
2 Total Access 352 2nd Generation 2
POTS/2 Ethernet SFU ONT
1287702G1 BVL3AP9D_ _
3 Total Access 352H 2nd Generation
SFU ONT
1287702G3 BVMB100F_ _
4 Total Access 362 2nd Generation 2
POTS/2 Ethernet/1 RF Overlay
SFU ONT
1287712G1 BVMB900F_ _
5 Total Access 364 2 POTS/4 Ether-
net/ 1 RF Overlay Outdoor ONT
1287713G1 NA
6 Total Access 362R 2nd Generation 2
POTS/2 Ethernet/1 RF Return SFU
ONT
1287715G1 BVMB300F_ _
Indoor ONTs
7 Total Access 324 SFU ONT 1287735G1 BVMB600F_ _
8 Total Access 324 SFU ONT with
UPS
1287735G2 BVMB700F_ _
9 Total Access 334 3rd Generation
SFU ONT with UPS
1287736G3 BVMBP10F_ _
Total Access 300 Series
Single Family Unit ONT
Figure 1. Outdoor ONT
NOTICE
In Figure 1, older models do not have access to the Power Connector from
the front of the module. To access the Power Connector on these units,
loosen the Telco Access screw and swing the module open.
Figure 2. Indoor ONTs
INSTALLATION GUIDELINES
NOTE
The Total Access 300 Series SFU ONT Installation and Maintenance Guide
(P/N 612877GONT-5) contains all information necessary to install, test,
and troubleshoot the ONTs supported in this Job Aid.
Surface Mounting
Hole
Surface
Mounting
Hole
Hinge
Hinge
Security
Screw
Two-screw
Terminal
Bridges
Ethernet
Connections
Fiber Optic
Cable
Ground
Power
Ethernet
POTS
Ground and Power
Drop Callout
Ground Drop
Fiber Drop
RING
TIP
RING
TIP
FXS 0/1
FXS 0/2
ETH 0/1
ETH 0/2
TIP
RING
ETH 0/1
ETH 0/2
POTS 1
POTS 2
POTS 2
POTS 1
TELCO ACCESS
ETH 1
TOTAL ACCESS 362
1287712G1
12V , 1.25A
POWER
NETWORK STATUS
TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
any working telephone into that jack.
If the telephone works, there is a problem inside the house.
If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.
CLEI
TEL. NUMBER
RF Connection
ETH 2
RF
+ 12VDC
12V RTN
SIG RTN
ON BAT
REP BAT
BAT MIS
LOW BAT
7654321
Total Access 324
PHONE
PWR
NET
1
2
1
2
3
4
ETH
PHONE 1
PHONE 2
NET
1
23
ETHERNET
4
RF
LOW BAT
BAT MIS
REP BAT
ON BAT
SIG RET
12V RET
+12V
ON/OFF PWR UPS POTS1 POTS2 ETH1 ETH2 ETH3 ETH4 CATV
POWER BATTERY FAIL ETH4 ETH3 ETH2 ETH1 POTS MGMT WLAN
3rd Generation
Issue Date: February 2015
Document P/N: 612877GONT-22B
Documentation for ADTRAN Carrier Networks products is
available for viewing and download directly from the
ADTRAN Support Community website.
Go to: https://supportforums.adtran.com/welcome
Registration is required.
ADTRAN offers training courses on our products, including
customized training and courses taught at our facilities or at
customer sites.
For inquiries, go to: http://adtran.com/training
The following related online documents and resources provide additional information for this product:
Total Access 300 Series SFU ONT Installation and Maintenance Guide
Total Access 5000 GPON User Interface Guide
Total Access 5000 Series Fiber to the Premises Deployment Guide
Total Access 5000 Series BBDLC Deployment Guide
Total Access 5000/5006 Engineering Guide

Other manuals for ADTRAN Total Access 362R

Questions and Answers:

ADTRAN Total Access 362R Specifications

General IconGeneral
BrandADTRAN
ModelTotal Access 362R
CategoryNetwork Hardware
LanguageEnglish

Summary

Required Tools and Supplies for ONT Installation

Gather Essential Tools and Supplies

Lists standard technician tools and specific items required for ONT installation, including levels, screwdrivers, crimpers, test sets, and optical tools.

Outdoor ONT Installation Procedures

Mounting the Outdoor ONT Enclosure

Details steps for securely mounting the outdoor ONT enclosure to a vertical surface, ensuring proper leveling and fastener usage.

Grounding the Outdoor ONT

Provides instructions for establishing a proper earth ground connection for the outdoor ONT, including wire routing and termination.

Wiring the Power and Alarm Connector

Explains how to correctly connect the power and alarm wiring to the ONT's electronics module, emphasizing proper connector handling.

Routing the Fiber Optic Drop Cable

Guides on routing the OptiTap fiber drop cable through the housing, ensuring it's not pinched when the module is closed.

Connecting the SC/APC Optical Cable

References the installation guide for complete information on connecting the SC/APC optical cable using a bulkhead adapter.

Wiring the Local Power Source

Advises on local power source wiring, deferring to the installation guide for specific on-site conditions and practices.

Installing the Uninterruptible Power Source (UPS)

Refers to the installation guide for UPS installation procedures, which depend on site conditions and local practices.

Connecting POTS Lines

Details connecting POTS (Plain Old Telephone Service) using two-screw terminal bridges or RJ-11 jacks.

Connecting RF Cable

Instructs on routing the RF cable through the enclosure and connecting it to the RF connector on the electronics module.

Connecting Ethernet Cable

Explains connecting CAT-6 rated Ethernet cables for Gigabit operation to the RJ-45 ETH socket on the ONT.

Indoor ONT Installation Procedures

Mounting the Indoor ONT

Provides guidance on selecting a location for the indoor ONT and mounting it, recommending below eye-level for visibility.

Connecting POTS for Indoor ONT

Details creating and connecting POTS cables to the indoor ONT's RJ-11 jacks, using an RJ-11 crimper.

Connecting Ethernet for Indoor ONT

Explains connecting CAT 5 or 6 rated cables to the NET connection for the indoor ONT's Gigabit Ethernet ports.

Connecting RF Video for Indoor ONT

Instructs connecting a standard male F-type connector coaxial cable to the RF connection on the indoor ONT.

Connecting External Power Supply

Refers to the installation guide for details on connecting the external power supply to the indoor ONT.

ONT LED Status Indicators

Understanding LED Status for Network and POTS

Details the meaning of LED indicators for Power, Network Status (OLT connection, ranging), and POTS status (off-hook, ringing).

Operational Specifications Overview

Key Operational Specifications

Lists critical operating parameters including voltage range, power consumption for various models, and optical transmit/receive specifications.

Maintenance and Support Information

Routine Maintenance and Repair

States that ONTs require no routine hardware maintenance and advises against field repairs, recommending returns for service.

Safety and Regulatory Compliance

Directs users to specific guides for Safety and Regulatory Compliance information pertaining to individual ONT models.

Related product manuals