Frame Data Parser for WISE LoRa modules v1.3.7
18
Advantech Co., Ltd., Copyright 2020
Write 0: clear the low alarm
status
Bit 2
Clear Maximum Sensor Value
1: Clear the maximum Sensor
value
Bit 3
Clear Minimum Sensor Value
1: Clear the minimum Sensor
value
Bit 4
Alarm update
Bit 5 ~ 15
(Reserved)
Status
0: Normal
1: Sensor failed
SenVal
Temperature or humidity value (0.001)
3.1.2 Accelerometer
Field Name
Data Type
Description
LogIndex
int
Index number of logged feature data, raw
data or FFT data
Time
int
The time to start measuring vibration
X-Axis,
Y-Axis,
Z-Axis
Object
X, Y, or Z Axis