Frame Data Parser for WISE LoRa modules v1.3.7
29
Advantech Co., Ltd., Copyright 2020
START_
SAMPLE_INDEX
Int
Start of Index number of FFT data for each
axis (X,Y,Z). Since each axis contains max 800
data, the range of the value is 0 to 799.
END_
SAMPLE_INDEX
Int
End of Index number of FFT data for each
axis (X,Y,Z). Since each axis contains max 800
data, the range of the value is 0 to 799.
DATA
Array
Array of FFT Data value, unit: mg.
3.2. Sample Output
{
"SequenceNumber": 110,
"TotalLength": 45,
"SourceAddress": null,
"TempHumi": {
"Range": 0,
"Event": 0,
"SenVal": 33312
},
"Accelerometer": {
"X-Axis": {
"SenEvent": 0,
"OAVelocity": 530,