Frame Data Parser for WISE LoRa modules v1.3.7
26
Advantech Co., Ltd., Copyright 2020
8 (0x08)
Memory parity error
9 (0x09)
Reserved
10 (0x0A)
Gateway path unavailable
11 (0x0B)
Gateway target device failed to respond
12 ~15
Reserved
16 (0x10)
Unavailable
17 (0x11)
Slave response timeout
18 (0x12)
Checksum error
19 (0x13)
Received data error
20 (0x14)
Send request fail
21(0x15)
Unprocessed
22(0x16)
Read only
23(0x17)
In processing
Data
int
The coil data, 0 or 1.
3.1.8 RS-485 Register Data
Field Name
Data Type
Description
Status
Int
The error status of polling this channel can
refer to Coil Status in the previous section.
Data
int
The register data with range 0 to 0xFFFF.